Description
• Fast-acting surface-mount fuse
• Satisfies the EIA/IS-722 Standard
• Solder immersion compatible
Electrical Characteristics
Note: 30vde constant current source required for 200% overload tests on 250mA-1A.
Agency Information
Electrical Characteristics
% of Amp Rating | Opening Time |
100% | 4 Hours Minimum |
200% (250mA-5A) | 5 Seconds Maximum |
250% (250mA-5A fuse) | 1 Second Maximum |
200% (7-15A fuse) | 20 Seconds Maximum |
250% (7-15A fuse) | 4 Seconds Maximum |
Agency Information
• UL Recognition Guide & File numbers: JDYX2 & E19180 (250mA - 15A)
• CSA Component Acceptance: File # 053787 C000, Class # 1422 30
Environmental Data
• Life test: MIL-STD-202, Method 108A, Test Condition D
• Load humidity: MIL-STD-202, Method 103B
• Moisture resistance: MIL-STD-202, Method 106E
• Terminal strength: MIL-STD-202, Method 211A
• Thermal shock: MIL-STD-202, Method 107D, air-to-air
• Case resistance: EIA/IS-722
• Resistance to dissolution of metallization: ANSI J-STD-002, Test D
• Mechanical shock: MIL-STD-202, Method 213B with exceptions per EIA/IS-722 Standard
• High frequency vibration: MIL-STD-202, Method 204D, Test Condition D
• Resistance to solvents: MIL-STD-202, Method 215A
Dimensions – mm/in
Drawing Not to Scale
Recomended Pad Layout – mm (in)
Recomended Pad Layout – mm (in)
Ordering
• Specify packaging and product code
(i.e., TR2/1025FA250-R)
Soldering Method
• Wave solder: 260°C, 10 Sec max.
• Infrared reflow: 260°C, 30 Sec max.
Specifications
Product Code |
Current Rating (amps) |
Voltage Rating AC DC |
Interrupting Rating (amps)* 250Vac 125Vdc 60Vdc |
DC Cold Resistance** (Ω) Typical |
Typical Melting I2t† |
Typical Voltage Drop‡ |
|||
1025FA250-R | 250mA | 250V | 125V | 50 | 50 | - | 4.7500 | 0.1212 | 2019mV |
1025FA500-R | 500mA | 250V | 125V | 50 | 50 | - | 1.1500 | 0.0415 | 1500mV |
1025FA750-R | 750mA | 250V | 125V | 50 | 50 | - | 0.5550 | 0.143 | 880mV |
1025FA1-R | 1 | 250V | 125V | 50 | 50 | - | 0.2800 | 1.750 | 560mV |
1025FA1.5-R | 1.5 | 250V | 125V | 50 | 50 | - | 0.1140 | 1.460 | 260mV |
1025FA2-R | 2 | 250V | 125V | 50 | 50 | - | 0.0750 | 6.086 | 258mV |
1025FA2.5-R | 2.5 | 250V | 125V | 50 | 50 | - | 0.0510 | 8.48 | 232mV |
1025FA3-R | 3 | 250V | 125V | 50 | 50 | - | 0.0384 | 18.15 | 205mV |
1025FA3.5-R | 3.5 | 250V | 125V | 50 | 50 | - | 0.0305 | 17.83 | 185mV |
1025FA4-R | 4 | 250V | 125V | 50 | 50 | - | 0.0275 | 23.32 | 190mV |
1025FA5-R | 5 | 250V | 125V | 50 | 50 | - | 0.0195 | 38.74 | 180mV |
1025FA7-R | 7 | 250V | 60V | 50 | - | 50 | 0.0116 | 138 | 150mV |
1025FA10-R | 10 | 250V | 60V | 50 | - | 50 | 0.0072 | 457 | 146mV |
1025FA12-R | 12 | 250V | 60V | 50 | - | 50 | 0.0056 | 498 | 120mV |
1025FA15-R | 15 | 250V | 60V | 50 | - | 50 | 0.0039 | 1451 | 110mV |
* AC interrupting rating (measured at designated voltage, 100% power factor random closing); DC interrupting rating (measured at designated voltage, time constant of
less than 50 microseconds, battery source)
** DC cold resistance (measured at ≤10% of rated current)
† Typical Melting I2t (measured with a battery bank at rated DC voltage, 10x-rated current, but not exceeding the interrupting rating. Time constant of calibrated circuit less
than 50 microseconds). Test current not to exceed interrupting rating of 50A.
‡ Typical voltage drop (measured at rated current after temperature stabilizes)
• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.
Time Current Curve
Packaging Code
Packaging Code Prefix | Description |
TR2 | 2,500 fuses on 24mm tape-and-reel on 13 inch (330mm) reel per EIA Standard 481 |