cooper bussmann

6125TD Series Time Delay Brick™ Fuses

  

Description
•Time Delay surface mount fuse
• Complies with EIA-IS-722 Standard
•Solder Immersion Compatible

ELECTRICAL CHARACTERISTICS
% of Amp Rating Opening Time
100% 4 Hours Minimum
200% 1 Second Minimum
200% 2-4 Seconds Typical
200% 60 Seconds Maximum


Agency Information
• UL Recognition Guide & File numbers:JDYX2 & E19180.
• CSA Component Acceptance: 053787 C 000 & Class No: 1422 30.
 
Environmental Data
• Life Test: MIL-STD-202, Method 108A, Test Condition D
• Load Humidity: MIL-STD-202, Method 103B
• Moisture Resistance: MIL-STD-202, Method 106E
• Thermal Shock: MIL-STD-202, Method 107D, air-to-air
• Case Resistance: EIA/IS-722
• Resistance to Dissolution of Metallization:ANSI J-STD-002, Test D
• Mechanical Shock:MIL-STD-202, Method 213B,Test Condition A
• High Frequency Vibration: MIL-STD-202, Method 204D,Test Condition D
• Resistance to Solvents: MIL-STD-202, Method 215A
 
Ordering
• Specify packaging and product code
(i.e., TR1/6125TD500-R)

Soldering Method
•Wave Immersion: 260°C, 10 sec max.
•Infrared: 260°C, 30 sec max.

Dimensions mm⁄(inches)


SPECIFICATIONS
Product
Code
Current
Rating
Voltage
Rating
AC            DC
Interrupting
Rating*
125VAC    60VDC
Resistance
(ohms)** Typ.
Typical
Melting
I2t†
Typical
Voltage
Drop‡
6125TD500-R 500mA 125V 60V 50A 50A 0.4025 0.716 245 mV
6125TD750-R 750mA 125V 60V 50A 50A 0.2350 1.07 250 mV
6125TD1-R 1A 125V 60V 50A 50A 0.1680 2.88 256 mV
6125TD1.5-R 1.5A 125V 60V 50A 50A 0.0630 2.35 125 mV
6125TD2-R 2A 125V 60V 50A 50A 0.0480 9.45 133 mV
6125TD2.5-R 2.5A 125V 60V 50A 50A 0.0350 16.2 130 mV
6125TD3-R 3A 125V 60V 50A 50A 0.0263 15.3 97 mV
6125TD3.5-R 3.5A 125V 60V 50A 50A 0.0195 14.5 95 mV
6125TD4-R 4A 125V 60V 50A 50A 0.0185 38.8 106 mV
6125TD5-R 5A 125V 60V 50A 50A 0.0133 34.4 100 mV
6125TD7-R 7A 125V 60V 50A 50A 0.0087 90.2 99 mV
* AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than 
50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I2
t (Measured with a battery bank at rated DC voltage, 10x-rated current (not to exceed IR), time constant of calibrated circuit less than 50 microseconds)
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures


TIME CURRENT CURVE


PACKAGING CODE
Packaging Code Description
TR1 1000 pieces of fuses on 12mm tape-and-reel on a 7 inch (177mm) reel per EIA Standard 481

 

----------------------------------
伊顿 EATON BUSSMANN 规格资料查询
伊顿 EATON BUSSMANN 规格类型
或许您会感兴趣...
联系客服
深圳市博孚美科电子有限公司
总机: 0755-82862885, 82862629
传真: 总机 转 801
邮箱: service@bussmann.net.cn
网址: http://www.bussmann.net.cn
资料中心: http://www.bm-bussmann.com