Fast-acting 690 volt CUBEFuse specifically designed to protect low-fault current conditions that occur in wind power generation systems.
The finger-safe feature minimizes exposure to live parts to reduce hazard to personnel and utilizes the integral 690 volt CUBEFuse holder to minimizes footprint.
The Wind CUBEFuse minimizes incident energy and reduces arc flash hazards utilizing Class J electrical characteristics and is UL 248 Recognized for low voltage fuses.
Catalog Symbol: WCF_RN
Description:
Finger-safe, fast-acting CUBEFuse for wind power generation.
Finger-safe, fast-acting CUBEFuse for wind power generation.
Electrical Characteristics:
Maximum clearing time at 200%
Maximum clearing time at 200%
rated current:
• 4 Minutes for 1 to 30A fuses
• 6 Minutes for 35 to 60A fuses
• 8 Minutes for 70 to 100A fuses
Agency Information:
• UL Recognized Fuse: Guide JFHR, File E56412
• cURus component certified C22.2
Other Ratings/Specifications:
Watts Loss at Rated Current: WCF15RN: 3.48W
WCF30RN: 5.45W
WCF60RN: 7.27W
WCF100RN: 11.50W
Operating and Storage Temperature Range: -40 to 90°C
Material Specifications:
• Case: Glass filled PES (Polyethersulfone)
• Terminals: Copper alloy
• Terminal plating: Electroless tin
Installation:
Fits 690V WCF holders as listed in the table
Application:
• Wind Systems:
- Transformer protection
- Pitch and speed control
- Turbine HVAC and lighting
Carton Quantity and Weight
Catalog Numbers (amp rating)
Carton Quantity and Weight
Amp Rating |
Carton Qty. |
Weight Per Carton | |
lbs | kg | ||
WCF1-30A | 12 | 1.39 | 0.63 |
WCF35-60A | 12 | 1.42 | 0.65 |
WCF70-100A | 6 | 1.74 | 0.79 |
Catalog Numbers (amp rating)
Non-Indicating Wind CUBEFuse | |||
WCF1RN | WCF20RN | WCF45RN | WCF90RN |
WCF3RN | WCF25RN | WCF50RN | WCF100RN |
WCF6RN | WCF30RN | WCF60RN | |
WCF10RN | WCF35RN | WCF70RN | |
WCF15RN | WCF40RN | WCF80RN |
Features and Product Benefits
• Maximize uptime and reliability using fuses designed and recognized to UL 248 for low voltage fuses
• Fast-acting protection specifically designed for low-fault current conditions that occur in wind power generation systems
• Minimize chances of equipment failure and personnel injury when using full range fuses having fast response time to low-magnitude faults
• Simplify compatibility with readily available industry standard Class CF holders while minimizing panel space by up to 80%
• Meets all UL specified overload opening requirements
• Minimizes incident energy and reduces arc flash hazards utilizing Class J electrical characteristics
• Finger-safe feature minimizes exposure to live parts, reducing hazard to personnel
WCF_RN Dimensions – in (mm)


Time-Current Characteristic Curves–Average Melt

Current Limitation Curves

Wind CUBEFuse Holders

WCF_RN Dimensions – in (mm)


Time-Current Characteristic Curves–Average Melt

Current Limitation Curves

Wind CUBEFuse Holders

Catalog Numbers(amps) | Fits 690V Wind CUBEFuse Holder | ||
WCF1RN | TCFH30NW | TCFH60NW | TCFH100NW |
WCF3RN | X | X | X |
WCF6RN | X | X | X |
WCF10RN | X | X | X |
WCF15RN | X | X | X |
WCF20RN | X | X | X |
WCF25RN | X | X | X |
WCF30RN | X | X | X |
WCF35RN | X | X | |
WCF40RN | X | X | |
WCF45RN | X | X | |
WCF50RN | X | X | |
WCF60RN | X | X | |
WCF70RN | X | ||
WCF80RN | X | ||
WCF90RN | X | ||
WCF100RN | X |
总机: 0755-82862885, 82862629
传真: 总机 转 801
邮箱: service@bussmann.net.cn
网址: http://www.bussmann.net.cn
资料中心: http://www.bm-bussmann.com