Description:
Fused and non-fused enclosed Rotary Disconnect Switches from 16 to 1200A in NEMA 1, 3R, 4, 4X, 12 enclosures.
 
Features
• UL 98 Listed for general purpose, main disconnect, or branch circuit protection up to 600Vac/dc
• UL 508 Listed for motor disconnect applications up to 600Vac
• Multiple field installed accessories enhance the enclosed disconnect switches to fit the desired application
• Lockout/tagout: Up to three 1⁄4˝ shank padlocks can be installed on external handles
 
Ratings:
• Volts: 600Vac; 250-600Vdc*
• Amps: 16-1200A
• Short-Circuit Current Ratings: UL 98: 25kA-200kA; UL 508: 10kA-65kA
*Some non-fused disconnect switches are not rated for DC applications.
 
Specifications
• Operating temperature: -20ºC to 70ºC
• 4X Plastic Enclosure Flammability Rating:
Polycarbonate UL 94-5VA-0
Fiberglass UL 94-5V
 
Agency Information
• UL 98 Listed: File E182262, Guide WIAX, WIAX7
• UL 508 Listed: File E155129, Guide NLRV, NLRV7
• cULus Listed to CSA Standard 22.2, No. 14
• cULus Listed to CSA Standard 22.2, No. 4
• Conforms with IEC 60947-3
• CE Compliant
• RoHS Compliant
 
Field Installed Accessories
• Auxiliary contacts
• Terminal shrouds
 
Available Cooper Bussmann Fuses
Class Type 
CC LP-CC Time-Delay, Current Limiting
CC FNQ-R Time-Delay
CC KTK-R Fast-Acting  
J LPJ Time-Delay, Current Limiting  
J JKS Fast-Acting Fuses 
J DFJ High Speed Drive Fuse
L KRP-C Time-Delay, Current Limiting 
L KTU Fast-Acting
L KLU Time-Delay




3-Pole UL 98 600Vac


Part Numbers
All part numbers provided with integral or installed lugs and a black selector handle.
Order red/yellow handle by changing the suffix “B” to “R.”
UL General Purpose Amp Rating NEMA Enclosure Type & Part Number
1 3R 4 4X Plastic(1) 4X Stainless 12
30 ER1-30N3SB ER3R-30N3SB ER4-30N3SB ER4P-30N3SB ER4X-30N3SB ER12-30N3SB
60 ER1-60N3SB ER3R-60N3SB ER4-60N3SB ER4P-60N3SB ER4X-60N3SB ER12-60N3SB
100 ER1-100N3SB ER3R-100N3SB ER4-100N3SB ER4P-100N3SB ER4X-100N3SB ER12-100N3SB
200 ER1-200N3PB ER3R-200N3PB ER4-200N3PB ER4P-200N3PB ER4X-200N3PB ER12-200N3PB
400 ER1-400N3PB ER3R-400N3PB ER4-400N3PB ER4P-400N3PB ER4X-400N3PB ER12-400N3PB
600 ER1-600N3PB ER3R-600N3PB ER4-600N3PB ER4P-600N3PB ER4X-600N3PB ER12-600N3PB
800 ER1-800N3PB ER3R-800N3PB ER4-800N3PB ER4P-800N3PB ER4X-800N3PB ER12-800N3PB
1200 ER1-1200N3PB ER3R-1200N3PB ER4-1200N3PB N/A ER4X-1200N3PB ER12-1200N3PB
(1) Enclosures ≤100A are polycarbonate, flammability rating UL 94-5VA-V0, ≥200A are fiberglass, flammability rating UL 94-5V.

Switch Ratings
Switch
Amp Rating
Disconnect
Switch
No. of
Poles
Voltage SCCR
@ Vac
Max Hp Rating
@ 600Vac
Vac Vdc
30 RD30-3 3 600 N/A 100kA 25
60 RD60-3 50
100 RD100-3 25kA/100kA*
200 RD200-3 250 200kA 200
400 RD400-3 350
600 RD600-3
800 RD800-3 N/A 100kA 500
1200 RD1200-3
* 25kA @ 600Vac, 100kA @ 480Vac.

Enclosure Weights - Lbs & Dimensions - in

Part
Number Family
Amp
Rating
NEMA Enclosure Type H x W x D Mounting Centers H x W Weight
Lbs
A B C
ER_-30   1, 3R, 4, 12 10x8x6 8.3x6.3     11
30 4X-SST 10x8x6   9.5x6.3 8.3x7.5 11
  4X-Plastic(1) 9x9x6   10x3.6 5.6x8 5
ER_-60   1, 3R, 4, 12 10x8x6 8.3x6.3     12
60 4X-SST 10x8x6   9.5x6.3 8.3x7.5 12
  4X-Plastic(1) 9x9x6   10x3.6 5.6x8 5
ER_-100   1, 3R, 4, 12 12x10x6 10.3x8.3     12
100 4X-SST 12x10x6   11.5x8.3 0.3x9.5 12
  4X-Plastic(1) 13x13x6   14x7.6 9.6x12 8
ER_-200   1, 3R, 4, 12 20x16x8 18.1x14.2     39
200 4X-SST 20x16x8   19.3x14.2 18.1x15.4 39
  4X-Plastic(1) 23x17x12   21.5x10.1   31
ER_-400   1, 3R, 4, 12 36x30x8 33.9x28.3     122
400 4X-SST 36x30x8   35.1x28.3 33.9x29.5 122
  4X-Plastic(1) 40x32x14   38.1x23.9   103
ER_-600   1, 3R, 4, 12 48x36x12 45.8x34.9     209
600 4X-SST 48x36x12   47x34.9 45.8x36.1 209
  4X-Plastic(1) 51x37x 14   50.1x28.5   187
ER_-800   1, 3R, 4, 12 48x36x12 45.8x34.9     211
800 4X-SST 48x36x12   47x34.9 45.8x36.1 211
  4X-Plastic(1) 51x37x 14   50.1x28.5   189
ER_-1200 1200 1, 3R, 4, 12 60x36x16 57.5x33.9     268
  4X-SST 60x36x16   58.7x33.9 57.5x35.1 268
(1) Enclosures ≤100A are polycarbonate, flammability rating UL 94-5VA-V0, ≥200A are fiberglass, flammability rating UL 94-5V.

Available Field-Installed Accessories - Order Separately

Auxiliary Contacts - for 30 to 1200 Amp Switches
Auxiliary
Switch
Amp Rating
Contacts  -
Contact
Type
for 30 to 1
Number of
Contacts
200 Amp Swit
Continuous
Amp Rating
ches
Voltage
Rating
Max Number of Aux
Contacts per Switch
Part
Number
30-100 NO + NC 1 of each 10A 240Vac 4 BAC01
30-100 NC 2 10A 240Vac 4 BAC02
100-1200 NO + NC 1 of each 10.1A 125-250Vac 2 BAC03*
100-1200 NO + NC 1 of each 10.1A 125-250Vac 2 BAC04*
100-1200 NO + NC 1 of each 1A 125Vac 2 BAC11*
100-1200 NO + NC 1 of each 1A 125Vac 2 BAC12*
* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.

Terminal Shrouds - for 200 to 800 Amp Switches
Switch
Amp Rating
Number
of Poles
Location
on Switch
Part
Number
30-100 3 Lineside and Loadside TSH3-3TB
200A 3 Lineside TSH4-3T
200A 3 Loadside TSH4-3B
400A 3 Lineside TSH5-3T
400A 3 Loadside TSH5-3B
600A 3 Lineside or Loadside TSH6-3TB
800-1200A 3 Lineside or Loadside TSH7-3TB

----------------------------------
伊顿 EATON BUSSMANN 规格资料查询
伊顿 EATON BUSSMANN 规格类型
或许您会感兴趣...
联系客服
深圳市博孚美科电子有限公司
总机: 0755-82862885, 82862629
传真: 总机 转 801
邮箱: service@bussmann.net.cn
网址: http://www.bussmann.net.cn
资料中心: http://www.bm-bussmann.com